Stud Welding Products

Home

Catalog
Equipment
studs
CD vs ARC
Field Applications
Contact Us
contact us

 

Shear Connector Studs (3/4 & 7/8" Diameter)

For welding to fillet or heel of angle, consult your SWA representitive for the correct ferrule part number.
3/4" DIAMETER SHEAR CONNECTORS
Stud Specifications
Ferrule specifications
D
H
A
Type
No.
D
B
F
M
3/4
1 1/4
3/8
 Flat Surface
FF-075
1.215
1.030
.469
.656
 
 
 
 Weld Through  Deck
FW-075
 
 
 
 
Standard Length
Pounds M Pieces
Part Number
3 3/16
486
SCO750318
3 3/8
509
SCO750337
3 7/8
572
SCO750387
4 3/16
611
SCO750418
4 3/8
640
SCO750437
4 7/8
707
SCO750487
5 3/16
736
SCO750518
5 3/8
579
SCO750537
5 7/8
855
SCO750587
6 3/16
861
SCO750618
7 3/16
987
SCO750718
8 3/16
1112
SCO750818
9 3/16
1240
SCO750918
10 3/16
1373
SCO751018

7/8" DIAMETER SHEAR CONNECTORS
Stud Specifications
Ferrule specifications
D
H
A
Type
No.
D
B
F
M
7/8
1 3/8
3/8
 Flat Surface
FF-087
1.408
1.210
.545
.732
Standard Length
Pounds M Pieces
Part Number
3 11/16
726
SCO870368
4 3/16
811
SCO870418
5 3/16
981
SCO870518
6 3/16
1153
SCO870618
7 3/16
1322
SCO870718
8 3/16
1473
SCO870818
9 3/16
1642
SCO870918
10 3/16
1800
SCO871018


All S.W.A shear connectors meet AWS specifications. Test reports available upon request.

SHEAR CONNECTOR STUDS are designed to effectively tie the concrete to steel beams and to resist shear loadings between the concrete slab and steel beam in composite construction. All orders for studs include required ferrules.

LENGTH: Length is before weld. Studs when welded to base metal will be approximately 3/16" shorter after weld and when welded through deck, 3/8" shorter after weld. Lengths for shear connector studs are generally set by governing specifications. Consult your SWA representitive for other lengths available for specific applications.

MATERIAL: Low carbon steel

STAINLESS STEELS: SC studs are also available in stainless steel

Mechanical Property Requirements
 
Type A1
Type B2
Tensile Strength
55,000 psi min
(380 MPa)
60,000 psi min
(415 MPa)
Yield Strength
(0.2% offset)
__
50,000 psi min
(345 MPa)
Elongation
(% in 2-in.)
17% min
20% min
Reduction of Area
50% min
50% min
1 Type A studs shall be general purpose of any type and size used for purposes other than shear transfer in composite beam design and construction.
2 Type B studs shall be studs that are heated, bent, or of other configuration in 1/2 in (12.7 mm), 5/8 in (15.9 mm), 3/4 in (19 mm), 7/8 in (22.2 mm), and 1 in (25.4 mm) diameter that are used as an essential component in composite beam design and construction.


Home | Equipment | C.D. Welders -vs- Arc Welders | Weld Studs | Field Applications
Boiler | JobSite | Quote Request | Catalog | E-mail Us

Copyright © Stud Welding Products, Inc. 1999, 2003; All Rights Reserved