Headed Concrete Anchor Studs (1/4″-5/8″)

Headed Anchor Studs are used in all types of concrete connections. they can be welded to a flat surface, or in the fillet, or on the heel of an angle with a stud welding system.

Ferrules: All orders for studs include required ferrules.

Length: Length is before weld. Stud diameters (D) 1/2 inch and below will be approximately 1/8 inch shorter after welding. 5/8 inch will be approximateley 3/16 inch shorter after welding. Made to order lengths are available upon request.

ESR-2577_Headed                  Ferrule Spec Sheet                           Shipping Weights 

LA City Approval_Headed

Mechanical Property Requirements
Type AType B
Tensile Strength61,000 psi min.65,000 psi min
Yield Strength49,000 psi min51,000 psi min
Elongation
(% in 2 in)
17% min.20% min.
Elongation
(% in 5x dia.)
14% min.15% min.
Reduction of Area50% min.50% min.
MaterialLow Carbon Steel (1010-1020) ASTM A29
Type A Studs are general purpose studs

Type B Studs are headed, bent, or of other configuration that are used as an essential component in composite beam design
Category: